logo
Shanghai Jianggong Valve Manufacturing Co., Ltd.
products
products
Home > products > Pipe Control Valve > Self-operated Electric Temperature Control Valve

Self-operated Electric Temperature Control Valve

Product Details

Place of Origin: China

Brand Name: JGPV

Payment & Shipping Terms

Minimum Order Quantity: 1set

Packaging Details: Plywood box safety packing

Delivery Time: 14 days

Payment Terms: L/C, T/T, Western Union

Supply Ability: 500 Set per month

Get Best Price
Highlight:
Application::
General
Certificate::
ISO9001, ISO14001
Medium Type::
Water, Steam And Oil Etc.
Connection::
Threaded / Flanged / Welded
Standard Or Non-Standard::
Standard
Flow Way::
Two Way
Actuation::
Manual, Electric, Pneumatic,Automatic
Sealing Performance::
Sealing
Working Temperature::
Normal Temperature And High Temperature
Pressure Application::
Normal Pressure
Quality Warranty::
18 Months
Application::
General
Certificate::
ISO9001, ISO14001
Medium Type::
Water, Steam And Oil Etc.
Connection::
Threaded / Flanged / Welded
Standard Or Non-Standard::
Standard
Flow Way::
Two Way
Actuation::
Manual, Electric, Pneumatic,Automatic
Sealing Performance::
Sealing
Working Temperature::
Normal Temperature And High Temperature
Pressure Application::
Normal Pressure
Quality Warranty::
18 Months
Self-operated Electric Temperature Control Valve

Highlight:Self-operated Electric Temperature Control Valve

 

 

Product introduction:

 

The core working principle of the self-operated electric temperature control valve is to drive the valve body through an electric actuator, changing the flow rate and direction of the fluid medium to achieve the purpose of temperature control. The electric actuator is composed of a servo motor, a reducer, a position sensor, etc., and features high precision and fast response. The self-operated temperature control valve, on the other hand, consists of a valve body, a valve core, a spring, and other components. It adjusts the position of the valve core by sensing temperature changes in the fluid medium, thereby regulating the flow rate and direction of the medium.

In the self-operated electric temperature control valve, when the temperature sensor detects a temperature change, it transmits a signal to the electric actuator. After receiving the signal, the electric actuator drives the valve body to adjust the position of the valve core, so as to regulate the flow rate and direction of the medium. During this process, the spring functions to provide an initial positioning force, ensuring the stability of the valve core in its initial position. At the same time, the spring can also provide a certain restoring force when the valve core is disturbed, ensuring that the valve core can quickly return to the correct position.

 

Product technical parameters:

 

DN(mm) 20 25 32 40 50 65 80 100 125 150 200
(10) (12) (15) (20)

Rated flow

Coefficient

 

 

Linear 1.8 2.8 4.4 6.9 11 17.6 27.5 44 69 110 176 275 440 690

Equal

percentage

1.6 2.5 4 6.3 10 16 25 40 63 100 160 250 400 630
Rated stroke(mm) 16 25 40 60
PN(MPa) 1.0 ~ 6.4

Inherent flow

characteristics

Linear, equal percentage

Inherently adjustable

ratio

50

Leakage

Rate

 

 

Single seat Hard seal: Class IV ; Soft seal: Class VI
Sleeve seat Hard seal: Class II; Soft seal: Class VI
Working temperature(℃) -20~200 -40~250 -40~450 -60~450

Signal range

mA.DC)

0~10 4~20
Action mode Electric close type and electric open type
Ambient temperature(℃) -20~70℃
Ambient humidity ≤95%
Power supply 220V 50Hz
 

 

Product features:

 

  1. Control Precision: Select temperature control valves with different precision levels based on actual process requirements to meet the control precision needs.
  2. Flow Range: Choose a suitable temperature control valve according to the actual process flow to ensure it can meet the requirements of flow control.
  3. Fluid Characteristics: Consider the properties of the fluid medium, such as viscosity and corrosiveness, and select appropriate materials and structures to ensure the service life and stability of the temperature control valve.
  4. Power Supply and Control Signal: Select the appropriate power supply and control signal based on actual needs to ensure the normal operation of the temperature control valve.
  5. Installation and Maintenance: Take factors such as installation space and pipeline connection method into account, as well as the convenience of maintenance and upkeep, to select a suitable temperature control valve.

 

Our Advantages:

 

Self-operated Electric Temperature Control Valve 0Self-operated Electric Temperature Control Valve 1Self-operated Electric Temperature Control Valve 2Self-operated Electric Temperature Control Valve 3Self-operated Electric Temperature Control Valve 4Self-operated Electric Temperature Control Valve 5